| STAGEMAKER® CONCERT HOISTS - LOW VOLTAGE CONTROL (CONFIGURATION B) |
|
|
|
|
STAGEMAKER® - CONFIGURATION B:
LOW VOLTAGE CONTROL FOR FIXED OR MOBILE INSTALLATION
|
Configuration B utilizes low voltage control. The hoist (SM1, SM5, SM10) is equipped so it can be mounted in inverted or normal position. Controller furnished seperately. A "pickle", which is used during stage setup, can be connected directly to the low voltage hoist control. The Sm16, SM20 and SM25 hoists must always be mounted in the normal position and are furnished with pushbutton pendent controller with E-stop.
|
|
|
|
|
 |
|
Inverted Position
|
|
Normal Position
|
HOIST FEATURES:
|
- Compact - for better space utilization on stage, in trusses and on the truck.
- Quiet Operation - can even used during performances.
- 5 - pocket load wheel provides exceptionally smooth operation and reduced chain wear.
- Anti-jam chain guide for precise chain alignment.
- Increased Safety - with combined load limiter / brake.
- 80 micron thick black epoxy paint finish.
- Class F insulated Hoisting Motor
|
- Electromechanica I disk brake.
- Solid-state brake control.1
- 360° upper / lower hook rotation.
- Vinyl chain container.
- Black load chain (SM1, SM5, SM10).
- Electro-zinc load chain (SM16, SM20, SM25).
- Ergonomic handles (SM1, SM5, SM10).
- 230V - 3Ph - 60Hz power supply.
- Pressure cast aluminum body.
|
| CONTROLLERS: |
ACCESSORIES:
|
- 4, 8 or 12 channel controller with remote configured for combined power / control or seperate power and control.
- Pistol-grip pushbutton controller or "Pickle" (SM1, SM5, SM10) with pigtail (standard pigtail length is 18", longer
lengths available). Plug is optional.
- Pushbutton controller with E-Stop button (SM16, SM20, SM25).
|
- Motor Cables
- Single and twin flight cases (SM5, SM10 only).

|
NOTE:
- A mainline contactor is not furnished on SM1 hoists.
- Mainline contactor is specially wired so it is always energized when power to the hoist (SM5 and SM10 only) is applied.
- The mainline contactor in the hoist control panel for the SM16, SM20, SM25 hoists is controlled by the E-Stop on the pushbutton controller.
|
|
TWO-HOIST, ONE CABLE ARRANGEMENT
|
TWO-HOIST, FOUR CABLE ARRANGEMENT
|
 |
|
CONFIGURATION B TECHNICAL DATA:
|
Capacity Tons
|
Model
|
Speed (fpm)
|
Falls
|
Dimensions (inches)
|
Power (HP)
|
Nominal
Current
230 V
|
Weight
of Unit (1)
(lbs)
|
Chain
weight
(lb/ft)
|
|
A
|
B
|
C
|
|
1/16
|
SM1 068 M2-B
|
32
|
1
|
12 1/4
|
8 1/2
|
12 1/4
|
0.33
|
2
|
29
|
0.148
|
|
1/16
|
SM1 0616 M1-B
|
64
|
1
|
12 1/4
|
8 1/2
|
12 1/4
|
0.33
|
2
|
29
|
0.148
|
|
1/8
|
SM1 128 M1-B
|
32
|
1
|
12 1/4
|
8 1/2
|
12 1/4
|
0.33
|
2
|
29
|
0.148
|
|
1/4
|
SM5 254 M1-B
|
16
|
1
|
16 1/4
|
9 1/4
|
16
|
0.65
|
2
|
58
|
0.363
|
|
1/4
|
SM5 258 M1-B
|
32
|
1
|
16 1/4
|
9 1/4
|
16
|
1.3
|
4
|
58
|
0.363
|
|
1/4
|
SM5 2516 M1-B
|
64
|
1
|
16 1/4
|
9 1/4
|
16
|
1.3
|
4
|
58
|
0.363
|
|
1/2
|
SM5 504 M1-B
|
16
|
1
|
16 1/4
|
9 1/4
|
16
|
0.65
|
2
|
58
|
0.363
|
|
1/2
|
SM5 508 M1-B
|
32
|
1
|
16 1/4
|
9 1/4
|
16
|
1.3
|
4
|
58
|
0.363
|
|
1/2
|
SM10 5016 M1-B
|
64
|
1
|
19
|
11 3/4
|
19 1/4
|
2.8
|
7.2
|
113
|
0.726
|
|
1
|
SM10 1004 M1-B
|
16
|
1
|
19
|
11 3/4
|
19 1/4
|
1.4
|
3.6
|
113
|
0.726
|
|
1
|
SM10 1008 M1-B
|
32
|
1
|
19
|
11 3/4
|
19 1/4
|
2.8
|
7.2
|
113
|
0.726
|
|
1 1/2
|
SM16 1608 M1-B
|
32
|
2
|
20 1//4
|
14
|
22
|
5.6
|
15.4
|
243
|
1.209
|
|
2
|
SM10 2002 M1-B
|
8
|
2
|
19
|
11 3/4
|
21 3/4
|
1.4
|
3.6
|
125
|
0.726
|
|
2
|
SM10 2004 M1-B
|
16
|
1
|
19
|
11 3/4
|
21 3/4
|
2.8
|
7.2
|
125
|
0.726
|
|
2
|
SM20 2008 M1-B
|
32
|
1
|
20 1//4
|
14
|
23 1/4
|
5.6
|
15.4
|
243
|
1.209
|
|
2 1/2
|
SM25 2506 M1-B
|
25
|
1
|
20 1//4
|
14
|
23 1/4
|
5.6
|
15.4
|
243
|
1.209
|
|
5
|
SM25 5003 M1-B
|
12.5
|
2
|
20 1//4
|
14
|
27 1/4
|
5.6
|
15.4
|
243
|
1.209
|
(1) approximate weight without chain
|
Back to top
CONFIGURATION B OPTIONS:
|
- Fixed body hook (SM5 and SM10)
- Upper and lower (weight-operated) limit switches - normal position only
- Self locking hook (SM5 and SM10)
- Geared limit switch
- Second brake (SM5 and SM10)
- Steel control enclosure for SM1
- Vinyl rain cover
- Drain hole in the load sprocket compartment (SM5 and SM10 only)
- Power pigtail - no plug (standard pigtail length is 18", longer lengths available)
|
- Control pigtail - no plug (standard pigtail length is 18", longer lengths available)
- Power & control pigtail length is 18", longer lengths available)
- Twist-Lock male plug for power pigtail
- 7 pin Socapex male plug for power & control pigtail
- Twist-Lock female receptacle for control pigtail
- Mating plug/receptacle for the supplied plug
- Custom plug for pigtail
- 460V - 3Ph - 60Hz or 208V - 3Ph-60Hz power supply
|
|